Child Care Equipment is one of our specialities. We produce & export a comprehensive range of hospital baby care equipment. Our high quality and safe child care equipment meets all the requirements of a Neonatal/Paediatric Set up.
The PSM Baby Care Equipments are produced, meeting the requirements of commonly accepted international quality standards. These child care products ensure full safety of neonates and infants.
Different models of Baby Incubators, Phototherapy Units, Infant Resuscitation Equipment, Foetal Heart Monitor, Foetal Doppler, Weighing Scales, Baby Basinets are among the products included in our Hospital Baby Care Equipment.
Product Details:
Minimum Order Quantity | 1 Piece |
Type | Transport Incubator |
Model Name/Number | INC-TRP |
Usage/Application | Hospital |
Castors | 5" PU |
Dimension | 49X23X53 inches |
Country of Origin | Made in India |
Alarms
• Skin temp low / high • Probe failure • Low battery • Power failure • System Failure • Timer
In case of high temperature i.e. above 380C, heater automatically cuts off thus ensuring baby’s safety.
Can be used on manual mode as well.
Collapsible Stainless Steel Stand
With 2/4 no. gas springs for ambulance and in hospital transport purposes. Gas spring system allow the stand to collapse when the lever is pulled and trolley is pressed from both the sides.
Temperature set range | 32 °C- 39 °C |
Temp variability | 1.0 °C |
Temp uniformity | 1.0 °C |
Air filter | removes airborne particles & dust |
Easy Access
Quick and easy access through the side access door and front port holes. The side door folds down and the matteress retracts out from the hood to access for emergency procedures. The door and tubing ports offer ventilator tubing support .Infant restraint strap attached to the baby bed.
Power Source
Transport incubator operates on AC or DC power using AC when available or switching to its internal battery when necessary
Battery : The batteries used in the system are 12 volt 18ah. Sealed maintenance free VRLA batteries.
Charge Time : 8-10 hrs. per battery from full discharge.
Hood options : Standard single wall / double wall hood (on demand).
Chassis Body : Plastic (fibre) to shock proof the system
Standard Features
• Single wall Hood • Skin temperature probe / Air temp. Probe • 2 access doors • 1 baby belt • Collapsible trolley
Optional
• Examination lamp • 2 disposable infant restraint straps • 1 iris port • 6 tubing ports • Accessory shelf • Suction, Oxygen cylinder, pressure regulatory assembly, Flow Meter, Remote Controlled movement of the Trolley.
Control Displays
Battery condition status | single led indication of low battery condition on the side panel |
Power mode | illuminates AC, DC or external DC |
Air/Baby temp °C | displays incubator air temp / baby temperature |
Dimensions in inches (Approx.)
Height without hood | 39″ |
In collapsible stand mode | 29″ |
height with hood | 49″ |
Width | 23″ |
Length | 53″ |
Baby bed | 20×11″ |
Weight | 75kg |
Backup | 60-90mns |
Size of Castors | 5″ PU |
Sealed maintenance free batter | VRLA Batteries Charge time : 10hrs.(Approx.) |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Power Supply | 220V/50Hz |
Heater Power | 650 Watts |
Wavelength | 450-470 |
Light Source | High Bright Blue/Whit LED's |
Country of Origin | Made in India |
Model-D open care system comes with automatic manual and baby (Servo) modes.
In addition, the Skin/Air temperature display is larger than other set temperature display. Skin temperature display can be converted form OC to OF by the push of a button. A big LCD is provided for more information and visualizations of the heater power in manual and servo modes. A full panel of alarms provides safety and convenience, with both audible and visual indicators in the event of:
• High Temp./ Low Temp. • Power Failure
• System Fail • Timer -On
• Probe Failure • Heater fail / ON (Optional) only visual alarm provided
Heater Assembly
The heater assembly located above the centre of the support structure consists of an integral examination light and a 650 watts heating system (Silica/ quartz /Ceramic Heater) for quick warming and even distribution of heat on the baby bed. The heater can be swivelled in either direction for taking X-ray and doing procedures. The Heater is also equipped with LED Phototherapy on both side to provide light intensity effective on the baby bed
Air Mode (Optional)
The system comes with air sensor. This is added security cover with exclusive feature of switching OFF the heater in case the AIR temperature goes above 390C irrespective of what the skin temperature is at the time of event
Technical Specification
Height | 1850mm |
Length | 1050mm |
Width | 650mm |
Power Supply | 220V/50Hz |
Heater Power | 650 Watts |
Fuse | 5 Amp |
Additional Features
If needed the unit can be programmed by the user itself for any of the following features:
(a) Count Up / down Timer.
(b) Check baby Alarm. (OPTIONAL).
(C) Pre warming mode
Manual Mode
The system automatically starts heating from 40% in manual mode and the same can be changed through settings Up to 100%. The system automatically converts from servo mode to manual mode in case of probe failure thus providing nonstop working of the unit.
Baby Bed
The spacious baby bed incorporates easy drop down/ fold down glasses for maximum access to the patient. Optional: X-Ray facility is provided below the baby bed for taking X-ray of the baby without disturbing
Led Phototherapy (Optional)
comes with choice of highly efficient and bright 12/15 choice of LED’s on each side of the heater. The strong lux of 24/30 LED’s cure jaundice in baby rapidly
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | NW |
Usage/Application | Nicu |
Material | Mild Steel |
Color | WHITE BLUE |
Height | 1920 MM |
Width | 860 MM |
Length Mm | 890 MM |
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event of
· DESCRIPTION
· Manual Mode
Facility of converting the warmer from servo mode to manual mode for non-stop working. The heat in the manual mode is locked at 50% to give more protection for the baby.
· Heater Assembly
The Heater assembly located above the center of the support structure consists of radiant heater and reflector with inbuilt halogen examination lamp for assessment of Infant color. The heater can be swivelled to either direction.
· Baby Bed
The attached spacious baby bed incorporates easy drop down glasses for maximum access to the patient.
· Castors
The system is fitted with 2″ high quality castors having brakes in front 2 castors. Antistatic castors can be fitted as on option for further safety in lieu of the standard castors.
· Technical Specification
Height |
1920mm |
Length |
890mm |
Width |
860mm |
Power Supply |
220V/50Hz |
Heater Power |
650 Watts |
Fuse |
5 Amp |
OPTIONAL
2 Trays below the baby bed for keeping consumables.
2 Drawers fitted below the baby bed.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Type | Baby Warmer |
Model Name/Number | Model-S |
Usage/Application | Nicu |
Color | WHITE BLUE |
Height | 1920 MM |
Width | 860 MM |
Length Mm | 890 MM |
Country of Origin | Made in India |
The digital, micro processor – based controller comes with a full spectrum of features. Two function control modes provide the clinician more flexibility while optimizing the thermal environment. Dual digital temperature displays allow easy visualization of patient temperature and set point.
DESCRIPTION
Control Panel
The Model- S Infant Radiant Warmer comes complete with automatic manual /baby (Servo)/Air modes. In addition, the Skin/Air temperature display is larger than other set temperature display. Skin temperature display can be converted form OC to OF by the push of a button. A big LCD is provided for more information and visualizations of the heater power in manual and servo modes. A full complement of alarms provides safety and convenience, with both audible and visual indicators in the event of :
• High Temp./ Low Temp. • System Fail • Probe Failure • Power Failure • Timer • Heater fail / ON (Optional) only visual alarm provided
Heater Assembly
The Parabolic heater assembly located above the centre of the support structure consists of an integral examination light and a 650 watts heating system (Silica or quartz /Ceramic Heater) for quick warming and even distribution of heat on the baby bed. The heater can be swiveled in either direction for taking X-ray and doing procedures.
Air Mode (Optional)
The system comes with air sensor. This is added security cover with exclusive feature of switching OFF the heater in case the AIR temperature goes above 390C irrespective of what the skin temperature is at the time of event.
Manual Mode
The system automatically starts heating from 40% in manual mode and the same can be changed through settings up to 100%. The system automatically converts from servo mode to manual mode in case of probe failure thus providing nonstop working of the unit.
Baby Bed
The spacious baby bed incorporates easy drop down/ fold down glasses for maximum access to the patient.
Optional: X-Ray facility is provided below the baby bed for taking X-ray of the baby without disturbing.
Additional Features
If needed the unit can be programmed by the user itself for any of the following features:
(a) Count Up / down Timer.
(b) Check baby Alarm.
(c) Pre warming mode.
Castors
The system is fitted with 4″ high quality castors having brakes in front 2 castors. Antistatic castors can be fitted as on option for further safety in lieu of the standard castors.
Optional : The system comes with check baby alarm ( 1 – 120min.)
Technical Specification
Height | 1850mm |
Length | 1050mm |
Width | 650mm |
Power Supply | 220V/50Hz |
Heater Power | 650 Watts |
Fuse | 5 Amp |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Type | Baby Warmer |
Model Name/Number | NWDX |
Usage/Application | Nicu |
Material | Mild Steel |
Color | WHITE BLUE |
Height | 1920 MM |
Width | 860 MM |
Length Mm | 890 MM |
Number Of Wheels | 4 |
Country of Origin | Made in India |
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event of
Probe Fail • Skin High • Skin Low • Power Fail
DESCRIPTION
Manual Mode
Facility of converting the warmer from servo mode to manual mode for non-stop working. The heat in the manual mode is locked at 50% to give more protection for the baby.
Heater Assembly
The Heater assembly located above the center of the support structure consists of radiant heater and reflector with inbuilt LED examination lamp for assessment of Infant color. The heater can be swiveled to either direction.
Baby Bed
The attached spacious baby bed incorporates easy drop down glasses for maximum access to the patient.
Castors
The system is fitted with 4″ high quality castors having brakes in front 2 castors. Antistatic castors can be fitted as on option for further safety in lieu of the standard castors.
Dimensions (Approx.)
Height- 1920mm x Length- 890mm x Width- 860mm
Electrical Specifications
Power Supply: 220V/50Hz
Heater Power: 650 Watts
Fuse: 5 Amp
Storage
The unit comes fitted with one drawer system which slides out for keeping consumables.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Type | Baby Warmer |
Model Name/Number | DX(E) |
Usage/Application | Nicu |
Color | WHITE BLUE |
Height | 1920 MM |
Width | 860 MM |
Length Mm | 890 MM |
Number Of Wheels | 4 |
LCD Display | YES |
Country of Origin | Made in India |
DX(E) Infant Radiant Warmer allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin /air/ manual control.
DESCRIPTION
Control Panel
The Model - DX(E) Infant Radiant Warmer comes with automatic manual and baby (Servo) modes.
In addition, the Skin/Air temperature display is larger than other set temperature display. Skin temperature display can be converted from °C to °F by the push of a button. A big LCD is provided for more information and visualizations of the heater power in manual and servo modes. A full complement of alarms provides safety and convenience, with both audible and visual indicators in the event of:
High Temp./ Low Temp.
Power Failure
System Fail
Timer
Probe Failure
Heater fail /ON (Optional) only visual alarm provided
Air Mode (Optional)
The system comes with air sensor. This is added security cover with exclusive feature of switching OFF the heater in case the AIR temperature goes above 39°C irrespective of what the skin temperature is at the time of event
Manual Mode
The system automatically starts heating from 40% in manual mode and the same can be changed through settings up to 100%. The system automatically converts from servo mode to manual mode in case of probe failure thus providing nonstop working of the unit.
Baby Bed
The spacious oval baby bed incorporates easy drop down/fold down glasses for maximum access to the patient. Optional: X-Ray facility is provided below the baby bed fortaking X-ray of the baby without disturbing
The First Breath
The Model - DX(E) Infant Radiant Warmer combines virtually all the technology a caregiver may need in situation needed for resuscitation. The neonate can be supplied with a constant oxygen flow through the oxygen humidifier when connected to an oxygen cylinder/wall unit. The motorized slow suction can be used with a simple flip of a switch. A digital apgar time is standard, which signals when 1, 5 and 10 minutes have elapsed.
Castors
The system is fitted with 4″ high quality castors having brakes in front 2 castors. Optional : Antistatic castors
Tray
The unit comes Two trays below baby bed for keeping consumables.
Phototherapy Unit (Optional)
The unit can be fitted with LED phototherapy unit or CFL under surface phototherapy unit.
Additional Features
If needed the unit can be programmed by the user himself for any of the following features: (A) Count Up / down Timer. (B) Check baby Alarm. (C) Pre warming mode.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Type | Baby Incubator |
Model Name/Number | INC 1723D |
Usage/Application | Hospital |
Castors | 4 |
Display Type | LCD |
LCD Display | YES |
Temperature Sensor | YES |
DESCRIPTION
A full complement of alarm provides safety convenience, with both audible and visual indicators :
Optional : Oxygen Delivery System, Electric Slow Suction, CFL Phototherapy
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Material | Mild Steel |
Usage/Application | Hospital |
Brand | PSM |
Color | White |
LCD Display | YES |
Country of Origin | Made in India |
Control Panel
Model-DX Open care System comes complete with automatic manual and baby (Servo) modes.
In addition, the Skin/Air temperature display is larger than other set temperature display. Skin temperature display can be converted form OC to OF by the push of a button. A big LCD is provided for more information and visualizations of the heater power in manual and servo modes. A full complement of alarms provides safety and convenience, with both audible and visual indicators in the event of :
• High Temp./ Low Temp. • System Fail • Probe Failure • Power Failure • Timer • Heater fail / ON (Optional) only visual alarm provided
Heater Assembly
The heater assembly located above the centre of the support structure consists of an integral examination light and a 650 watts heating system (Silica or quartz /Ceramic Heater) for quick warming and even distribution of heat on the baby bed. The heater can be swiveled in either direction for taking X-ray and doing procedures.
Air Mode (Optional)
The system comes with air sensor. This is added security cover with exclusive feature of switching OFF the heater in case the AIR temperature goes above 390C irrespective of what the skin temperature is at the time of event.
Manual Mode
The system automatically starts heating from 40% in manual mode and the same can be changed through settings up to 100%. The system automatically converts from servo mode to manual mode in case of probe failure thus providing nonstop working of the unit.
Baby Bed
The spacious baby bed incorporates easy drop down/ fold down glasses for maximum access to the patient.
Optional : X-Ray facility is provided below the baby bed for taking X-ray of the baby without disturbing.
The First Breath
The open care system combines virtually all the technology a caregiver may need in situation needed for resuscitation. The neonate can be supplied with a constant oxygen flow through the oxygen humidifier when connected to an oxygen cylinder/wall unit. The motorized slow suction can be used with a simple flip of a switch. A digital apgar time is standard, which signals when 1, 5 and 10 minutes have elapsed.
Castors
The system is fitted with 4″ high quality castors having brakes in front 2 castors. Optional : antistatic castors
Storage
The unit comes fitted with two drawer system which slides out for keeping consumables.
Phototherapy Unit (Optional)
The unit can be fitted with LED phototherapy unit or CFL under surface phototherapy unit.
Additional Features
If needed the unit can be programmed by the user himself for any of the following features:
(a) Count Up / down Timer. (b) Check baby Alarm. (c) Pre warming mode.
Technical Specification
Height | 1924mm |
Length | 1090mm |
Width | 760mm |
Power Supply | 220V/50Hz |
Heater Power | 650 Watts |
Fuse | 5 Amp |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Model Name/Number | LED DOUBLE SURFACE |
Product Type | PHOTOTHERAPY |
Usage/Application | Hospital |
Voltage | 100-240 V |
Frequency | 50-60Hz |
Surface Size | 50 cm X 30 cm. |
Is It Portable | Portable |
Country of Origin | Made in India |
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate .
This has been achieved by exposing the infant to bright light (approximately 4.5 micro watts/sq cm/nm) in the range of 420-480 nm wave length by use of conventional phototherapy unit has been one of PSM most important focus in the field of neonatalogy for many years.In order to remove the limitation of fluorescent and CFL tubes, PSM has utilised long lasting, durable, more efficient and cost effective LEDs with more than double the flux as against what is radiated from conventional, fluorescent and CFL, for jaundice treatment.
Parameter
Electrical
Input voltage 100-240 V, 50-60Hz
Technical Specification
Front | 18” (L)x 10” (w) x3”(H) |
Height (adjustable) | Min 1230 mm, Max 1600mm |
Length | 800mm |
Width | 720mm |
Backside | 18” x 8.5” x 3” |
Baby Bassinet
Optional
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model | Restohealth 03 |
Pressure Range (cm H2O) | 300 Pa - 1000 Pa (3 cm H2O - 10 cm H2O). |
Operating Mode | CPAP (BUBBLE CPAP) mode. |
Pressure Range | 0 LPM-1 0 LPM (Varies in different Air- Oxygen blender). |
Type | Auto CPAP |
Country of Origin | Made in India |
Newborn / Pediatric CPAP Continuous Positive Airway Pressure Ventilation Support System.
Additional Feature
Neonatal continuous positive airway pressure support system with nasal or nasal congestion CPAP (Nasal-CPAP) will continue to positive air flow into the airway CPAP ventilator. Refers to the spontaneous breathing conditions, the patient should have a stable respiratory drive force and the appropriate tidal volume, in the entire breathing cycle of artificial imposition of a certain degree of positive airway pressure, which is conducive to prevent airway collapse, increase the functional residual capacity , Improve lung compliance, and improve oxygenation. In this mode, the ventilator only maintains a certain positive airway pressure, without mechanical ventilation. For spontaneous breathing of the newborn, to provide continuous positive pressure ventilation support.
Product Superiority:
CPAP pressure generator
Technical Specification
Ventilation mode ( MODE) | CPAP (BUBBLE CPAP) mode. |
The scope of application | Applicable to spontaneous breathing of the newborn, to provide continuous positive pressure ventilation support. |
Flow regulation LPM | 0 LPM-1 0 LPM (Varies in different Air- Oxygen blender). |
Oxygen concentration O2% | 21% -100% |
CPAP pressure | 300 Pa – 1000 Pa (3 cm H2O – 10 cm H2O). |
Pressure warning | Sound alarm (Pneumatic alarm). |
Indicator light | On indicates that the device is in operation. |
Working noise | Not more than 55dB (A). |
Gas input | Medical oxygen 0.3MPa-0.4MPa. |
Power supply | Ac 220V ± 22V , 50Hz ± 1Hz. |
Additional Information:
Product Details:
Minimum Order Quantity | 5 Piece |
Operation | Oxygen Therapy |
Usage/Application | Hospital |
Material | Polycarbonate |
Color | Transparent |
Packaging Type | Box Packing |
Product Type | Oxygen Hood |
Country of Origin | Made in India |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | LED SINGLE SURFACE |
Usage/Application | Hospital |
Voltage | 100-240 V, 50-60Hz |
Frequency | 50-60Hz |
Surface Size | 50 cm X 30 cm. |
Country of Origin | Made in India |
This has been achieved by exposing the infant to bright light (approximately 4.5 micro watts/sq cm/nm) in the range of 420-480 nm wave length by use of conventional phototherapy unit has been one of PSM most important focus in the field of neonatalogy for many years.In order to remove the limitation of fluorescent and CFL tubes, PSM has utilised long lasting, durable, more efficient and cost effective LEDs with more than double the flux as against what is radiated from conventional, fluorescent and CFL, for jaundice treatment.
Parameter
Electrical
Input voltage 100-240 V, 50-60Hz
Technical Specification
Front | 18” (L)x 10” (w) x3”(H) |
Height (adjustable) | Min 1230 mm, Max 1600mm |
Length | 800mm |
Width | 720mm |
Backside | 18” x 8.5” x 3” |